DC Current Sensor
AC Current Sensor
Measuring Instruments
SPECIFICATIONS | |
---|---|
Withstanding Voltage | AC 3700V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature | -10℃ to ~ 60℃ < 70%RH ( without condensation ) |
Accuracy | (23℃±5℃ 80%RH or less) |
Operating Temperature | 0℃ to ~ 40℃ < 80%RH ( without condensation ) |
Power supply | SR-44(1.55V)×2 or LR-44×2 |
Power consumption | 5mW |
Weight | Approx. 100g |
Measuring Range | AC Current:30A/300A (2 ranges auto) AC Voltage:3V~500V (4 ranges auto, 50/60Hz) DC Voltage:300mV~500V(5 ranges auto) Resistance:300Ω/3000Ω (2 ranges auto) |
AC Conversion | Average sensing rms reading |
Safety standard | IEC61010-1, IEC61010-2-032 Installation CategoryⅡ 600V or CategoryⅢ 300V |
Jaw opening capability | 40mmφ |
Limitation of circuit voltage | Less than AC 500V |
Size | 64(W)×193(H)×24(D)mm |
Accessories | Soft case:1 Instruction manual:1 Test lead:1 Batteries LR-44(1.55V):2 |
Display | 3.5 digit LCD max. reading of 3200 |
Over range indication | "OL" mark on LCD |
Data hold indication | "DH" mark on LCD |
Low battery indication | "B" mark on LCD |
Auto power off | Approx. 10 minutes later after the power on. |
E.M.C. standard | EN 50081-1 and EN 50082-1 |
Measuring method | Dual slope integration mode |
AC Current (ACA) | 0~300A:±2%rdg±8dgt |
AC Voltage(ACV) | 0~500V:±2.3%rdg±6dgt |
DC Voltage (DCV) | 0~500V:±1.3%rdg±3dgt |
Resistance (Ω) | 0~3000Ω:±2%rdg±5dgt |
Sampling time | 2 times/sec |
Battery life | SR-44(200 hours), LR-44(100 hours) |