DC Current Sensor
AC Current Sensor
Measuring Instruments
SPECIFICATIONS | |
---|---|
Measuring function | AC current, AC/DC voltage and Resistance |
Measuring method | Clamp CT |
Jaw opening capability | 55mmφ |
Measuring ranges | AC 2000mA/200A/1000A manual AC/DC 2V~600V auto Resistance 200Ω~20MΩ auto |
Change of measuring range | By rotary switch |
AC current detection | Dual integration mode |
Display | Max.1999 count on LCD with annunciator |
Over range indication | Blanking of all digits except MSD1 |
Data hold indication | "DH" mark on LCD |
Sampling rate | 2 times/sec. |
Low battery indication | "B" mark on LCD |
Circuit voltage | less than AC/DC 600V |
Operating temperature | 0~40℃, < 80%RH (without condensation) |
Storage temperature | -10~60℃, < 70%RH (without condensation) |
Auto power off | Approx. 10 minutes after power on |
Power supply | Battery “AAA” size (1.5V) × 2 |
Dimension | 85(W)×240(H)×34(D)mm |
Accessories | Carrying Case, Test Lead, Batteries, Instruction Manual |
Accuracy | 23℃±5℃, less than 80%RH ~A (50/60Hz) Manual range Range:200mA / 200A / 1000A Accuracy:±1.2%rdg±10dgt / ±1.2%rdg±10dgt / ±1.2%rdg±8dgt Max. input:AC 2000A(30 seconds) ~V (50/60Hz) DCV Auto range Range:2V / 20V / 200V / 600V Accuracy:±0.7%rdg±5dgt / ±1.2%rdg±5dgt / ±1.2%rdg±5dgt / ±1.2%rdg±5dgt Max. input:AC/DC 600Vrms Ω(OHM) Auto range Range:200Ω / 2KΩ / 20KΩ / 200KΩ / 2000KΩ / 20MΩ Accuracy:±1.2%rdg±5dgt / ±1.2%rdg±5dgt / ±1.2%rdg±5dgt / ±1.2%rdg±5dgt / ±1.2%rdg±5dgt / ±3%rdg±10dgt Max. input:Input protection 250Vrms(30seconds) Continuity check Range:2KΩ Accuracy:Continuity beeper <Approx. 300 Ω Max. input:250Vrms Diode Test Range:2V Accuracy:±10%rdg±3dgt Max. input:250Vrms |