DC Current Sensor
AC Current Sensor
Measuring Instruments
SPECIFICATIONS | |
---|---|
Measuring method | Dual slope integration mode |
Measurement range | AC20mA/200mA/2A/20A/200A/1000A/Auto |
Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Range/Resolution/Accuracy AC 20mA/0.01mA/±2.0% rdg ± 5 dgt AC 200mA/0.1mA/±2.0% rdg ± 5 dgt AC 2A/1mA/±2.0% rdg ± 5 dgt AC 20A/10mA/±2.0% rdg ± 5 dgt AC 200A/0.1A/±2.0% rdg ± 5 dgt AC 1000A/1A/±2.0% rdg ± 5 dgt |
Filter function | Low pass filter : 150Hz |
Max Memory function | "Max" mark on LCD with maximum value |
Auto power function | It power-off approximately 10-minutes after final operation. This function will be disabled during MAX-hold/ Bluetooth is on. |
Over range indication | Only the manual ranges are displayed up to 110% of the setting range (Excluding 1000A range). "OL" mark on LCD |
Data hold indication | "DH" mark on LCD with data hold value |
Low battery indication | "Battery" icon on LCD |
Sampling | 2 times/sec |
Jaw opening capability | 80mm x 74mm |
Withstanding Voltage | AC 3700V 1 minute max. (Between the core of CT and outer case) |
Limitation of circuit voltage | Less than AC 600V (EN61010 Installation category CAT III 300V) |
Operating Temperature | 0℃ to 50℃, 85%RH max. (Without condensation ) |
Storage Temperature | -10℃ to 60℃, 80%RH max. (Without condensation ) |
Power supply | 1.5V (AM-4, LR03 or AAA)×3 |
Size | 138(W)×237(H)×46(D)mm |
Weight | Approx. 650g |
Accessories | Hard carrying case:1 Instruction manual:1 Batteries:3 |