DC Current Sensor
AC Current Sensor
Measuring Instruments
SPECIFICATIONS | |
---|---|
Measuring method | Dual slope integration mode |
Display | 3.5 digit LCD, max. reading of 3200 |
Sampling | 2 times/sec(Digital display) 12 times/sec(Bar graph display) |
Low battery indication | "Battery" mark on LCD |
Over range indication | "OL" mark on LCD |
Data hold indication | "DH" mark on LCD |
Auto power off | Approx. 10 minutes later after power on |
Withstanding Voltage | AC 2200V 1 minute max. (Between the core of CT and outer case) |
Operating Temperature | 0℃ to 40℃, 80%RH max. ( Without condensation ) |
Storage Temperature | -10℃ to 60℃, 70%RH max. ( Without condensation ) |
Power supply | 1.55V (SR-44, LR-44)×2 |
Power consumption | 5mW |
Battery life | Approx. 50 hours(LR-44) |
Size | 64(W)×180(H)×21(D)mm |
Weight | Approx. 135g |
Accessories | Soft case:1 Instruction manual:1 Batteries LR-44(1.55V):2 |
40mmφCT | |
---|---|
Jaw opening capability | 40mmφ |
Range | AC 0~30/300mA, 30/300A, 2range manual |
Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Range/Resolution/Accuracy AC 30/300mA/0.01mA/±1.2% rdg ± 5dgt AC 30/300A/0.01A/0~200A : ±1.2% rdg ± 5dgt 200~250A : ±3.0% rdg ± 5dgt 250~300A : ±5.0% rdg ± 5dgt |
U type CT | |
---|---|
Max.size of conductor | 20mmφ |
Range | AC 300A |
Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Cable type/Resolution/Accuracy Single phase IV cable/0.1A/Approx. ±5% Parallel VVF cable/0.1A/Approx. ±5% Three phase VVR cable/0.1A/Approximate value |