DC Current Sensor
AC Current Sensor
Measuring Instruments

| SPECIFICATIONS | |
|---|---|
| Measuring method | Dual slope integration mode |
| Display | 3.5 digit LCD, max. reading of 1999 |
| Measuring ranges | AC 20 mA/200 A/500 A |
| Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Range/Resolution/Accuracy 20 A//0.01A/±2.0%rdg±5dgt 200 A/0.1A/±2.0%rdg±5dgt 500 A/1A/±2.0%rdg±5dgt(0~400A) 500 A//1A/±2.5%rdg±5dgt(401~500A) |
| Inside diameter of CT | φ33mm |
| Withstanding voltage | AC 14000V/1 minute |
| Over range indication | "OL" mark on LCD |
| Data hold indication | "DH" mark on LCD |
| Low battery indication | "B" mark on LCD |
| Sampling rate | 2 times/sec |
| Operating temperature | 0~40℃, < 80%RH (without condensation) |
| Power supply | AA manganese battery UM-3×2 |
| Dimension | 76(W)×311(H)×42(D)mm |
| Weight | Approx. 285g |
| Accessories | Carrying case, Batteries, Instruction manual |