DC Current Sensor
AC Current Sensor
Measuring Instruments

| SPECIFICATIONS 1 | ||||
|---|---|---|---|---|
| Range | 30mA | 300mA | 3000mA | 100A |
| Resolution | 0.01mA | 0.1mA | 0.1mA | 0.1A |
| Accuracy | ±1%rdg ±5dgt | |||
| SPECIFICATIONS 2 | |
|---|---|
| Measuring function | AC leakage current AC Load current |
| CT shape | Split clamp type circular ZCT |
| CT inside diameter | 35mm |
| Measuring frequency | 50 ~ 60Hz |
| Sampling rate | 2 time/1s |
| Measurement of temperature | Reference value displayed at “Multi-Tracer” |
| Operation | Power ON/OFF (other function is at a paired unit) |
| Low battery indication | Light up of LED on the main-body |
| Applicable circuit voltage | AC600V |
| Insulation resistance | More than 10MΩ by DC1kV insulation tester (Between CT~Universal connector) |
| Withstanding voltage | AC3.7kV/1min (Between CT and the Universal connector) |
| Operating Temperature and Humidity Range | 0~40℃ less than 80%RH (without condensation) |
| Storage Temperature and Humidity Range | -10~60℃ less than 70%RH (without condensation) |
| Power supply | LR03*3ea |
| Dimensions | 215.4*86*Φ55mm |
| Weight | 380g |
| Optional accessory | MDU-100X/MDU-200X (display unit) |