DC Current Sensor
AC Current Sensor
Measuring Instruments
Clamp sensor/Current detection part | |
---|---|
Sensing method | Split type CT with array of hole element sensors |
Inside diameter of CT | φ450mm |
Lead length | Approx.2m (From measuring unit to CT) |
Measuring part | |
---|---|
Mesuring function | AC (RMS)/DC current |
A/D Conversion | Dual slope integration method |
Measuring ranges | AC/DC 3A/30A/300A |
Accuracy | ±10%rdg±10dgt |
Min. resolution | 0.001A |
Range selector | 3 range manual by rotary switch |
Sampling rate | 2 times/sec |
Display | LCD max.3200 count with annunciators |
Over range indication | "OL" mark on LCD |
Data hold indication | "DH" mark on LCD |
Low battery indication | "B" mark on LCD |
Data hold function | Freeze the displayed value by D.H switch |
Zero(offset) adjustment | By zero(0) SET switch (DC current only) |
Auto power off | Approx. 10 minutes after power on |
General specification | |
---|---|
Limitation of circuit voltage | Less than AC 600V |
Operating temperature | 0~45℃, < 85%RH (without condensation) |
Storage temperature | -10~60℃, < 70%RH (without condensation) |
Withstanding voltage | AC 2200V/1 minute |
Power supply | 1.5V(AA size or UM-3) battery×6 |
Dimension | Main unit:159(W)×105(H)×53(D)mm |