SPECIFICATIONS 1 | ||||
---|---|---|---|---|
Range | 30mA | 300mA | 3000mA | 100A |
Resolution | 0.01mA | 0.1mA | 0.1mA | 0.1A |
Accuracy | ±1%rdg ±5dgt |
SPECIFICATIONS 2 | |
---|---|
Measuring function | AC leakage current AC Load current |
CT shape | Split clamp type circular ZCT |
CT inside diameter | 35mm |
Measuring frequency | 50 ~ 60Hz |
Sampling rate | 2 time/1s |
Measurement of temperature | Reference value displayed at “Multi-Tracer” |
Operation | Power ON/OFF (other function is at a paired unit) |
Low battery indication | Light up of LED on the main-body |
Applicable circuit voltage | AC600V |
Insulation resistance | More than 10MΩ by DC1kV insulation tester (Between CT~Universal connector) |
Withstanding voltage | AC3.7kV/1min (Between CT and the Universal connector) |
Operating Temperature and Humidity Range | 0~40℃ less than 80%RH (without condensation) |
Storage Temperature and Humidity Range | -10~60℃ less than 70%RH (without condensation) |
Power supply | LR03*3ea |
Dimensions | 215.4*86*Φ55mm |
Weight | 380g |
Optional accessory | MDU-100X/MDU-200X (display unit) |