DC Current Sensor
AC Current Sensor
Measuring Instruments

| SPECIFICATIONS | |
|---|---|
| Measuring method | Dual slope integration mode | 
| Display | 3.5 digit LCD, max. reading of 4000 | 
| Measuring ranges | AC 0-40mA, 400mA, 4A, 40A, 300A, AC 0~500V  | 
| Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Range/Resolution/Accuracy AC Current/40mA/0.01mA/±1.0%rdg±8dgt AC Current/400mA/0.1mA/±1.0%rdg±8dgt AC Current/4A/0.001A/±1.0%rdg±8dgt AC Current/40A/0.01A/±1.0%rdg±8dgt AC Current/300A/0.1A/±1.0%rdg±1%FS AC Voltage/500V/0.1V/±1.0%rdg±8dgt  | 
| Accuracy for Harmonics Current and Voltage | Fundamental, 3rd, 5th, 7th : 1%rdg±5dgt±AC current and voltage accuracy 11th and 13th Harmonics : 2%rdg±5dgt±AC current and voltage accuracy (Min. fundamental input current : more than 2% of each current)  | 
| AC Conversion | Average sensing rms reading | 
| Input Frequency | 45-65Hz | 
| Influence of external magnetic field | Less than 5mA (nearby 100A conductor) | 
| Inside diameter of CT | φ40mm | 
| Withstanding voltage | AC 2200V/1 minute | 
| Limitation of circuit voltage | Less than AC 500V | 
| Over range indication | "OL" mark on LCD | 
| Data hold indication | "DH" mark on LCD | 
| Low battery indication | "Battery" icon on LCD | 
| Sampling rate | 2 times/sec | 
| Operating temperature | 0~40℃, < 80%RH (without condensation) | 
| Storage temperature | -10~60℃, < 70%RH (without condensation) | 
| Power supply | 1.5V ("AAA" sixe, um-4)x3 | 
| Dimension | 70(W)×223(H)×34(D)mm | 
| Weight | Approx. 440g | 
| Accessories | Carrying case, Batteries, Test lead, Instruction manual |