DC Current Sensor
AC Current Sensor
Measuring Instruments

| SPECIFICATIONS | |
|---|---|
| Measuring function | AC current, AC voltage, Resistance | 
| Measuring method | Clamp CT | 
| Jaw opening capability | 40mmφ | 
| Measuring ranges | AC 40mA/400mA/4A/40A/500A AC 1.0~500V Resistance 2kΩ/20kΩ/200kΩ  | 
| Change of measuring range | By rotary switch | 
| Filter function | Low pass filter : 150Hz | 
| Display | Max.1999 count on LCD with annunciator | 
| Over range indication | "OL" mark on LCD | 
| Data hold indication | "DH" mark on LCD | 
| Sampling rate | 2 times/sec. | 
| Low battery indication | "B" mark on LCD | 
| Circuit voltage | less than AC/DC 600V | 
| Operating temperature | 0~40℃, < 80%RH (without condensation) | 
| Storage temperature | -10~60℃, < 70%RH (without condensation) | 
| Auto power off | Approx. 10 minutes after power on | 
| Power supply | Battery “AAA” size (1.5V) × 3 | 
| Dimension | W70×H223×D34mm | 
| Weight | Approx. 440g | 
| Accessories | Carrying Case, Test Lead, Batteries, Instruction Manual | 
| Accuracy | 23℃±5℃, less than 85%RH ~A (50/60Hz) Range:40mA / 400mA / 4A / 40A / 500A Accuracy:±1%rdg±10dgt / ±1%rdg±10dgt / ±1%rdg±10dgt ±1%rdg±10dgt / ±1%rdg±3%F.S ~V (50/60Hz) Range:500V Accuracy:±1%rdg±10dgt Ω(OHM) Range:2kΩ / 20kΩ / 200kΩ Accuracy:±1%rdg±10dgt / ±1%rdg±10dgt / ±1%rdg±10dgt  |