DC Current Sensor
AC Current Sensor
Measuring Instruments
SPECIFICATIONS | |
---|---|
Rated Primary Current | DC200mA |
Applicable Current | 0~±200mA |
Max. Capable Current | DC10A |
CT Inside Diameter | φ20mm |
Output Voltage | ±2V F.S |
Accuracy | ±1.0% F.S.±10mV |
Response Time | Approx. 100ms |
Power Supply | +5V±5%(Unipolar) |
Power Consumption | Approx. 30mA |
Wiring Method | +:+5V 0V:COM REF:Ref OUT:Output |
Rated Voltage | Less than DC500V for low voltage circuit of coated wires |
Withstanding Voltage | AC3700V/1 minute (between output terminal and CT) |
Insulation Resistance | More than 100MΩ by 500V insulation tester (between output terminal and CT) |
Operation Temperature | -20~80℃, less than 85%RH w/o condensation |
Dimension | 42.9×42.4×22.3mm |
Weight | Approx. 27g |
Standard | Compliant with RoHS directive |