We specialize in Current Sensors, CT Sensors, and Measuring Instruments.

HOME
back
DC/AC Leakage Current Measurement

FDAZCT-11L-0.4 DC/AC Earth Leakage Current Measurement

FEATURES

Bipolar ±15V Power Supply.
Output ±5V at primary nominal current.
Applicable Frequency DC-18kHz.
Inside Diameter:φ11mm
DOWNLOAD
SPECIFICATIONS
Rated Primary Current DC/AC400mA
Applicable Current 0~±800mA
Max. Capable Current ±800mA
CT Inside Diameter φ11mm
Applicable Frequency DC, 40Hz~18kHz
Output Voltage ±5V F.S
Accuracy ±1% F.S
Response Time Approx. 60ms
Power Supply DC±15V±5% (Bipolar)
Power Consumption Approx. 30mA
Wiring Method M:Output COM:COM -Vcc:-15V +Vcc:+15V
Rated Voltage Less than DC/AC500V for low voltage circuit of coated wires
Withstanding Voltage AC2500V/1 minute (between output terminal and outer case)
Insulation Resistance More than 500MΩ by 500V insulation tester (between output terminal and CT)
Operation Temperature -20~85℃, less than 75%RH w/o condensation
Dimension 30×30×19.2mm
Weight Approx. 25g
Environmental Standard Conforming RoHS Directive
PAGE TOP