We specialize in Current Sensors, CT Sensors, and Measuring Instruments.

HOME
back
Clamp type AC Current Sensor/with DC Voltage Output

RCT-18 Leakage current measurements, AC 0.1mA~100mA, φ18mm,DCV output

FEATURES

Leakage current measurements with DCV output for recorder
AC 0.1mA~100mA
SPECIFICATIONS
Rated Primary Current AC10mA/100mA
Applicable Current 0.1mA~10mA/100mA
Max. Capable Current AC10mA Range : 15mA
AC100mA Range : 110mA
CT Inside Diameter φ18mm
Applicable Frequency 50/60Hz
Output Voltage ±100mV F.S
Accuracy ±2% F.S
Power Supply LR-44×2
Input Resistrance More than 1MΩ
Output Part Lead Wire: Approx. 1200mm(with Banana Plug)
Wiring Method Red:Output + Black:Output -
Rated Voltage Less than AC600V for low voltage circuit of coated wires
Withstanding Voltage AC2200V/1 minute (between output terminal and CT)
Insulation Resistance More than 100MΩ by 500V insulation tester (between output terminal and CT)
Operation Temperature 0~60℃, less than 80%RH w/o condensation
Dimension 45×140×20.4mm
Weight Approx. 100g
PAGE TOP