| SPECIFICATIONS | |
|---|---|
| Detection Principle | Fixed potential electrolysis method | 
| Gas Ventilation Method | Diffusion formulation | 
| Detection Range | 0~300ppm, Integrated concentration value display | 
| Response Time | within 30sec | 
| Alarm Setting Value | First step: 50ppm Second step: 150ppm | 
| Alert Method | Buzzer, Red lamp blinking, LCD display, Vibration | 
| Other Functions | Battery residual display, Peak hold, Peak value memory, Alarm functions (Sensor abnormality, Battery residual, Zero adjustment failure) | 
| Power Supply | AAA size alkaline battery×1 | 
| Dimension | W65×H64×D22mm | 
| Weight | 75g | 
| Accessory | Safety pin adapter |