DC Current Sensor
AC Current Sensor
Measuring Instruments

| SPECIFICATIONS | |
|---|---|
| Withstanding Voltage | AC 5500V, 1 minute (between operation handle and core of CT) | 
| Storage Temperature | -10℃ - 60℃, less than 70%RH (Without condensation) | 
| Accuracy | 23℃±5℃ 80%RH or less (50/60Hz) Range/Resolution/Accuracy(50/60Hz) AC 30A/0.01A/±1.5%rdg±8dgt AC 300A/0.1A/±1.5%rdg±8dgt AC 3000A/1A/±2.0%rdg±8dgt  | 
| Operating Temperature | 0℃ - 40℃, less than 80%RH (Without condensation) | 
| Power supply | 1.5V battery[UM-4 or AAA size]x 2 | 
| Power consumption | Approx. 6mW | 
| Measuring Range | AC30A/300A/3000A (50/60Hz) 3 ranges manual  | 
| AC Conversion | AC coupled true rms responding | 
| Safety standard | IEC61010-1, IEC61010-2-032 Installation Category. CategoryⅢ600V  | 
| Limitation of circuit voltage | Less than AC 600V | 
| Accessories | Battery (UM-4):2 Instruction Manual:1 Carrying Case:1 Hand Strap:1  | 
| Display | LCD, max. 3200 count with annunciators | 
| Dimension and weight | 194(W) x 341.5(H) x 52(D) mm, Approx. 1.8kgs | 
| Measuring function | AC load current | 
| Over range indication | "OL" mark on LCD | 
| Data hold indication | "DH" mark on LCD | 
| Low battery indication | "Battery" mark on LCD | 
| Measuring method | Dual slope integration mode | 
| Battery life | Approx. 200 hours continuous | 
| Sampling | 2 times/sec | 
| Auto power off function | The meter is set to power off Approx. 10 minute later after power on. | 
| Max Jaw Opening capability | 108mm (108x128mm) |