We specialize in Current Sensors, CT Sensors, and Measuring Instruments.

HOME
back
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)

ZCT-1100 Leakage current measurements of main cable, AC 1mA~3000A, 128mm×108mm

FEATURES

Leakage current measurements of main cable
Ultra big CT window
AC 1mA~30A : 3080turns
AC 30A~3000A : 2000turns
DOWNLOAD
SPECIFICATIONS
Rated Primary Current AC3000A
Applicable Current 1mA~3000A
Max. Capable Current 3600A
Secondary Windings 1mA~30A (Red/Black) 3080Turns
30A~3000A(White/Green) 2000Turns
CT Inside Diameter 128×108mm
Applicable Frequency 10Hz~5kHz
Output Example AC51.1mV±2%(10A/10Ω/White・Green)
Recommendable Load Resistor 1~200Ω
Output Part Lead Wire: Approx. 1000mm
Rated Voltage Less than AC600V for low voltage circuit of coated wires
Withstanding Voltage AC2200V/1 minute (between output terminal and CT)
Insulation Resistance More than 100MΩ by 500V insulation tester (between output terminal and CT)
Operation Temperature 0~60℃, less than 80%RH w/o condensation
Dimension 194×341.5×52mm
Weight Approx. 1800g
PAGE TOP