Current Sensor for Outdoor Use
CT-41B Current Sensor for Outdoor Use
FEATURES
Equivalent to protection grade IP67
 
 
| SPECIFICATIONS | 
| Rated Primary Current | 
AC800A(50/60Hz) | 
| Rated Secondary Current | 
0.2A | 
| Max. Capable Current | 
800A | 
| CT Inside Diameter | 
φ41mm | 
| Applicable Frequency | 
50Hz~2kHz | 
| Comparative Error | 
±0.5% In | 
| Phase Accuracy | 
±1.0° In | 
| Overcurrent Intensity | 
12.5kA / 2sec. | 
| Rated Burden (VA) | 
0.64VA | 
| Open Protection | 
24V (Zener diode) | 
| Output Part | 
Lead Wire:Approx. 7000mm | 
| Rated Voltage | 
Less than AC600V for low voltage circuit of coated wires | 
| Withstanding Voltage | 
AC2000V/1 minute (between output terminal and Core) | 
| Insulation Resistance | 
More than 100MΩ by 500V insulation tester (between output terminal and CT) | 
| Operation Temperature | 
-20~60℃ | 
| Dimension | 
97×134×42mm | 
| Weight | 
Approx. 600g | 
| Standard | 
Compliant with RoHS directive |