DC Current Sensor
AC Current Sensor
Measuring Instruments

| Insulation resistance | |
|---|---|
| Rated voltage and effective measuring range | MIS-2D:125V-20MΩ,250V-50MΩ,500V-100MΩ MIS-3D:250V-50MΩ,500V-100MΩ,1000V-2000MΩ MIS-4D:125V-20MΩ,250V-50MΩ,1000V-2000MΩ  | 
| Minimum measurable resistance at rated voltage | MIS-2D:0.125MΩ,0.25MΩ,0.5MΩ MIS-3D:0.25MΩ,0.5MΩ,1MΩ MIS-4D:0.125MΩ,0.25MΩ,1MΩ  | 
| Rated current | 1mA+20%-0% | 
| Open circuit voltage | Rated voltage+30%-0% | 
| Short circuit current | <2mA | 
| SPECIFICATIONS | |
|---|---|
| Withstanding Voltage | AC 3700V, 1 minute (Between input terminal and outer case) | 
| Storage Temperature | -10℃~60℃, 80% RH max (Without condensation) | 
| Operating Temperature | 0℃ to 40℃, 80% RH max. (Without condensation) | 
| Power supply | 1.5V (AM-3, R6 or "AA" size)×6 | 
| Weight | Approx. 330g (Excluding batteries) | 
| Safety standard | IEC 61010-1 Installation categoryⅡ, 600V phase to earth.  | 
| Size | 170(W)×105(D)×54(H)mm | 
| Accessories | Line test lead:1 Earth test lead:1 Batteries:6 Test lead case:1 Belt:1 Instruction manual:1  | 
| Display | 3.5 digit LCD with bar graph display, max. reading of 3200 count and annunciators | 
| Optional accessory | Test probe with remote switch | 
| Data hold indication | "DH" mark on LCD readout | 
| Low battery indication | Battery mark on LCD readout | 
| E.M.C. standard | EN 61326 | 
| Function | Insulation resistance, AC voltage | 
| Constructional standard | In accordance with IEC1557-2 or JIS C1302 (1994) | 
| Overload protection | 120% of the highest nominal output voltage (10 sec.) | 
| Battery check | DC 6.3V~9.5V | 
| Temperature characteristics(0~40℃) | ±5% rdg of specified accuracy | 
| Accuracy(DC 125V) | Measuring range:0~20MΩ~OL(∞) First effective range:0.02MΩ~10MΩ<±5%rdg Second effective range:0.01MΩ~0.02MΩ 10MΩ~20MΩ <±10%rdg Other range:100MΩ~OL(∞) :Accuracy is not Specified  | 
| Accuracy(DC 250V) | Measuring range:0~50MΩ~OL(∞) First effective range:0.05MΩ~20MΩ<±5%rdg Second effective range:0.02MΩ~0.05MΩ 20MΩ~100MΩ <±10%rdg Other range:100MΩ~OL(∞) :Accuracy is not Specified  | 
| Accuracy(DC 500V) | Measuring range:0~100MΩ~OL(∞) First effective range:0.1MΩ~50MΩ <±5%rdg Second effective range:0.05MΩ~0.1MΩ 50MΩ~100MΩ <±10%rdg Other range:100MΩ~OL(∞) :Accuracy is not Specified  | 
| Accuracy(DC 1000V) | Measuring range:0~2000MΩ~OL(∞) First effective range:2MΩ~1000MΩ <±5%rdg Second effective range:1MΩ~2MΩ 1000MΩ~2000MΩ <±10%rdg Other range:100MΩ~OL(∞) :Accuracy is not Specified  | 
| AC voltage (50/60Hz) | Range/Accuracy/Input impedance/Maximum input voltage AC 600V/±2.5% of full scale/Approx. 20M/AC 600V rms  | 
| Response time | Less than 5 sec. (Auto ranging) | 
| Infinity indication | "OL" mark on LCD readout (Over 3200 count) |