We specialize in Current Sensors, CT Sensors, and Measuring Instruments.

HOME
back
Clamp type DC/AC Current Sensor/with Voltage Output

LAD-240 DC current measurements,DC 1A~200A, φ30mm,DCV output

FEATURES

Compact size
With DC voltage output
DC 1A~200A
DOWNLOAD
SPECIFICATIONS
Rated Primary Current DC200A
Applicable Current 0~±200A
Max. Capable Current 220A
CT Inside Diameter φ30mm
Applicable Frequency DC only
Output Voltage ±200mV F.S
Accuracy 0~150A ±(2.0%rdg+0.5% F.S)
150~200A ±(2.5%rdg+0.5% F.S)
Power Supply LR-44×2
Input Resistrance More than 1MΩ
Output Part Lead Wire: Approx. 1200mm(with Banana Plug)
Wiring Method Red:Output + Black:Output -
Rated Voltage Less than DC250V for low voltage circuit of coated wires
Withstanding Voltage AC1500V/1 minute (between output terminal and CT)
Insulation Resistance More than 100MΩ by 500V insulation tester (between output terminal and CT)
Operation Temperature 0~40℃, less than 80%RH w/o condensation
Dimension 44×146×20.5mm
Weight Approx. 100g