Clamp type AC/DC current sensor/ With voltage output
DC CURRENT SENSOR
Clamp type DC current sensor / With voltage output
LAD-240
(DC current measurements, DC 1A~200A, φ30mm, DCV output)
LAD-250
(AC/DC current measurements, AC/DC 1A~1000A, φ40mm, DCV output)
DCT-10
(AC/DC current measurements, AC/DC 0.1A~10A, φ23mm, DCV output)
DCT-100
(AC/DC current measurements, AC/DC 1A~100A, φ23mm, DCV output)
DCT-1000
(AC/DC current measurements, AC/DC 1A~1000A, φ40mm, DCV output)
LAD-20
(AC/DC current measurements,AC 20A/DC 30A, φ17mm,DCV output)
List of AC Current sensor
List of DC Current sensor
HOME
Page to TOP
LAD-20
PRODUCTS
FEATURES
High frequency response DC to 100kHz.
Data output function.
Design to use with oscilloscope.
AC adaptor is optionally available.
Compliant with RoHS directive.
SPEC
SPECIFICATIONS
CT type
:
Clamp method
Safety standard
:
IEC 61010-1,IEC61010-2-032,Installation
CategoryⅡ 600V or Category Ⅲ 300V
Current detecting method
:
Magnetic balance method
Measuring range
:
AC 0~20Arms
DC 0~±30A
Output voltage
:
100mV/A
Accuracy
:
±1%rdg ± 5mA (DC~100kHz)
(23℃±5℃, 80%RH or less)
Frequency characteristic
:
-1.5dB(DC ~100kHz)
Output impedance
:
>10kΩ//<100pF
Temperature coefficient
:
0.013%/℃
Positioning error of conductor
:
<1%
Jaw opening capability
:
φ17mm
Output cable and connector
:
2m length, BNC connector
Limitation of circuit voltage
:
Less than AC/DC 300V
Withstanding voltage
:
AC 3700V 1 minute max. (Without AC adaptor)
Operating temperature
:
-10℃ ~ 60℃, 15%~85%RH( without condensation )
Storage temperature
:
-20℃ ~ 85℃, <80%RH( without condensation )
Power supply
:
9V Alkaline battery (6LR61)×1 or AC Adaptor
Power consumption
:
Approx. 20mA (at 0A input)
Size
:
70(W)×192(H)×25(D)mm
Weight
:
Approx. 280g
Accessories
:
Carrying case
:
1
Batteries
:
1
Instruction manual