Split and low V/A type AC current transformer (CTS Series)

CTS-200

PRODUCTS
CTS-200 FEATURES
  • 1A output for metering application.
  • Short circuit switch for secondary output is provided for safe operation.
  • High accurate transformer for the application of first class meter.
  • Easy installation by metal fitting.
■ CHARACTERISTIC OF OUTPUT VOLTAGE
CHARACTERISTIC OF OUTPUT VOLTAGE
SPEC
SPECIFICATIONS
Rated Primary Current : AC 200A
Rated Secondary Current : 1A
Rated Burden (VA) : 0.2VA
Accuracy : ±1.0%In
Phase Accuracy : ±1.0°In
Output Characteristic : Refer to the drawing
CT Inside Diameter : φ35mm
Max. Input Current : AC 240A
Open Circuit Protection : Short-circuit switch for output
Applicable Frequency : 50/60Hz
Max. Circuit Voltage : Less than AC600V for insulated cable
Withstanding Voltage : AC 2200V/1 minute
(between output terminal and outer case)
Insulation Resistance : More than 100MΩby 500V insulation tester
(between output terminal and outer case)
Operational Temperature : -10~50℃, less than 80%RH
Without condensation
Material of Outer Case : ABS Resin (Flame rating:compliant with UL-94V-0)
Material of Core : Silicon Steel
Dimension/Weight : 127(W)×40(D)×95(H)mm/ Approx. 550gs.
Standard : Compliant with RoHS directive