SPECIFICATIONS | |
---|---|
Measuring Range | pH: 0.00~14.00 ORP: 0~±2000mV Ion: Depends on the electrode in use Temp: 0~100.0℃(excluding ion electrode) |
Display Range | pH: pH-2.00~16.00 ORP: 0~±2000mV Ion:0.0~19.9 / 20~199 μg / L:0.20~1.99 / 2.0~19.9 / 20~199 mg / L:0.20~1.99 / 2.0~19.9 / 20~199 / 200~999 g / L(Automatic range switching) Temp: -5.0~110.0℃ |
Repeatability | pH: ±0.02pH ORP: ±2mV Ion: ±0.5% FS Temp: Within ±0.2°C |
Performance Guaranteed Temperature, Humidity | 0 to 45°C 20 to 90% or less (non-condensing) |
Interval Measurement function | Setting interval: 1 second to 99 minutes 59 seconds or 2 minutes to 99 hours 59 minutes can be arbitrarily set. |
Other Functions | Data hold:Stable judgment value: Fixed. Auto Power Off:OFF/10 min./30 min./60 min./180 min./360 min./720 min. settable. |
Power Supply | AA size alkaline battery×2/rechargeable NiMH batteries |
Power consumption | 0.1VA (when using a battery 3V) |
Dimension | W70×H188×D39mm |
Weight | 300g |
Data Memory | 1500 data (measurement time, measurement value, Temperature) |
Calibration History Creation Function | Last 1 batch (When used with "Cal-Memo" pH/ionic electrodes, the last 2 calibrations can be saved, including those on the electrodes) |
pH calibration | JIS pH standard solution, US standard solution up to 5-point calibration or custom-made standard solution up to 2-point calibration |
Temperature Calibration | One-point calibration |
Ion calibration | Up to 3-point calibration |
Combined electrode | |
---|---|
pH electrode set | HM-40P (main unit) + GST-2739C (1m):HM40P - 1 - 1CB0 HM-40P (main unit) + GST-2739C (3m):HM40P - 1 - 1EB0 HM-40P (main unit) + GST-2739C (5m):HM40P - 1 - 1IB0 HM-40P (main unit) + GST-2739C (11m):HM40P - 1 - 1QB0 |
ORP electrode set | HM-40P (main unit) + PST-2739C (1m):HM40P - 1 - 2AB0 HM-40P (main unit) + PST-2739C (5m):HM40P - 1 - 2IB0 HM-40P (main unit) + PST-2739C (11m):HM40P - 1 - 2QB0 |
Ion electrode | Fluoride ion combined electrode F-2021:0.019~19,000mg/L(pH5~6) Chloride ion combined electrode CL-2021:1~35,000mg/L(pH5~6) Cyanide ion combined electrode CN-2021:0.003~26mg/L(pH12~13) Sodium ion combined electrode NA-2011:2.3~23,000mg/L(pH10~11) Potassium ion combined electrode K-2031:0.39~3,900mg/L(pH5~6) Calcium ion combined electrode CA-2031:0.4~40,000mg/L(pH5~6) Nitrate ion combined electrode N-2031:0.62~62,000mg/L(pH5~6) Ammonia electrode AE-2041 (Membrane electrode):0.09~1,800mg/L(pH12 or more) Carbon Dioxide electrode CE-2041 (Membrane electrode):Dissolved gas1.49~1,490mg/L Bromide ion combined electrode BR-2021:0.8~80,000mg/L(pH5~6) Iodide ion combined elecrrode I-2021:0.01~127,000mg/L(pH5~6) Cadmium ion combined electrode CD-2021:0.01~1,120mg/L(pH5~6) Copper ion combined electrode CU-2021:0.06~630mg/L(pH5~6) Silver ion combined electrode AG-2021:0.1~108,000mg/L(pH5~6) Sulfide ion combined electrode S-2021:0.3~32,000mg/L(pH13 or more) |
Other electrode(individual and optional) | pH combined electrode GST-5841S(For organic solvent)(1m):GST5841S - 0 - AN0 pH combined electrode ELP-040(For hydrofluoric acid bath=The glass electrode is affected by fluorinated acid solution. However, because this product is a replaceable type glass electrode tip, a reduction in operating costs can be expected. In regards to measuring the 1% fluorinated acid solution (at 25℃ , for 1 min.), approximately 1000 measurements can be performed. Glass electrode chip replaceable Glass electrode chip 5082L)(1m):ELP040 - 0 - AN pH combined electrode GST-5821C(General, Glass body)(1m):GST5821C - 0 - AN0 |
Reference electrode internal solution | Powder reagent for phthalate pH4.01 standard solution 5 bags (each bag for 500 mL):143F191 Powder reagent for phthalate pH6.86 standard solution 5 bags (each bag for 500 mL):143F192 Powder reagent for phthalate pH9.18 standard solution 5 bags (each bag for 500 mL):143F193 Reference electrode internal solution RE-4 50 mL (3 bottles):0BG00011 ORP check solution (pH4.01 standard solution 500 mL + quinhydron powder):143F196 Abrasive for ORP electrode 10 mL:AO-001 |
Optional accessory | Ion sensor replacement liquid junction (10 pieces):For all ion combination electrodes (except AE/CE-2041):0LF00001 F Standard Solution F-1000 500mL:For F-2021 F:1000 mg/L:143F391 Cl Standard Solution CL-1000 500mL:For CL-2021 Cl:1000 mg/L:143A281 Na Standard Solution NA-1000 500mL:For NA-2011 Na:1000 mg/L:143E031 K Standard Solution K-1000 500mL:For K-2031 K:1000 mg/L:143B482 Ca Standard Solution CA-1000 500mL:For CA-2031 Ca:1000 mg/L:143B481 NO3 Standard Solution NO3-1000 500mL:For N-2031 NO3:1000 mg/L:143C486 NO3-N Standard Solution NO3-N 500mL:For N-2031 NO3 -N:1000 mg/L:143C487 NH4 Standard Solution NH4-1000 500mL:For AE-2041 NH4:1000 mg/L:143A041 NH4-N Standard Solution NH4-N 500mL:For AE-2041 NH4-N:1000 mg/L:143A042 Carbon dioxide electrode calibration powder CGS-111 For 1 L (10 packs):For CE-2041:143D044 Br Standard Solution BR-1000 500mL:For BR-2021 Br:1000 mg/L:143C483 IS tandard Solution I-1000 500mL:For I-2021 I:1000 mg/L:143H091 Cd Standard Solution CD-100 500mL:For CD-2021 Cd:100 mg/L:143B500 Cu Standard Solution CU-100 500mL:For CU-2021 Cu:100 mg/L:143D043 Ionic strength adjuster TISAB-01 500mL For F(1143A279 (TISAB-01):For general sample):For F-2021 For general sample:143A279 Ionic strength adjuster TISAB-11 500mL For F(1143A279 (TISAB-01):For general sample):For F-2021 For sample containing metal ion (iron, aluminum etc.):143A280 Ionic strength adjuster ISA-CL 500 mL For Cl、Br、I、Ag:For AG/CL/BR/I-2021:143A334 Ionic strength adjuster ISA-CN 500 mL For CN:For CN-2021:143A335 Ionic strength adjuster ISA-NA 500 mL For Na:For NA-2011:143A338 Ionic strength adjuster ISA-K 500 mL For K:For K-2031:143A337 Ionic strength adjuster ISA-CA 500 mL For Ca:For CA-2031:143A333 Ionic strength adjuster ISA-NO 500 mL For NO3:For N-2031:143A340 Ionic strength adjuster ISA-NH 500 mL For NH4:For AE-2041:143A339 Ionic strength adjuster ISA-CO 500 mL For CO2:For CE-2041:143D045 Ionic strength adjuster ISA-CU 500 mL For Cu、Cd:For CU/CD-2021:143A336 Ionic strength adjuster powder ISA-S For 100 mL (10 packs) For S:For S-2021:143A332 Reference electrode internal solution RE-1 100 mL:For the internal solutions of all ion combination electrodes (except AE/CE-2041) Reference external solution for CA-2031, I/S-2021:143F230 Reference electrode external solution RE-2 100 mL:Reference external solution for NA-2011,CL/BR/CN/CD/CU/AG/F-202:143F238 Reference electrode external solution RE-3 100mL:Reference external solution for K/N-2031:143F239 Ammonia electrode internal solution RE-NH4 50 mL (3 bottles):For AE-2041:0BG00005 Carbon dioxide electrode internal solution RE-11 500 mL:For CE-2041:143D042 Ammonia electrode replacement membrane (10 membranes):For AE-2041:AE-FILM Carbon dioxide electrode membrane cartridge (4 cartridges):For CE-2041:CTC-211 Carbon dioxide electrode calibration cell:For CE-2041:CGC-202L Calibration adapter For Carbon dioxide electrode:For CE-2041:67911490K |