2CT Method Mini Digital Clamp Leaker
PRODUCTS
|
New measuring method for AC leakage current
Model 2002
This is new measuring method for AC leakage current for single phase power system.
It is useful when working at the field where it is difficult to clamp the whole phase conductors(L&N).
|
FEATURES
- Compact size and light weight for convenient field use.
- True rms reading with wide range from 1mA to 200A.
- Extensional measurements by combination with optional auxiliary CT.
|
Measuring Example
-
There are many single phase panel (breaker) boards which is composed of the single pole breakers. In such panel board,L phase conductor is separated from N phase conductor and it is difficult to clamp whole phase conductors(L&N) by CT.
New 2CT method enabled the measurements of leakage current for such panel board
as showed below.
|
|
≫ Catalog PDF
|
SPEC
| SPECIFICATIONS |
| Measuring function |
: |
AC leakage current(By 2CT) AC leakage current (By main CT) AC load current |
| Jaw opening capability |
: |
40mm φ (Main CT) 5mm φ (Auxiliary CT) |
| Measuring ranges |
: |
0 ~ 200mA/2000mA (Leakage current) 0 ~ 20mA/200A (Load current) |
| A/D conversion |
: |
Dual slope integration method |
| AC conversion |
: |
True rms responding |
| Display |
: |
LCD max. 9999 count with annunciators |
| Sampling rate |
: |
2 time/sec. |
| Over range indication |
: |
"OL" mark on LCD |
| Data hold indication |
: |
"DH" mark on LCD |
| Low battery indication |
: |
"B" mark on LCD |
| Limitation of circuit voltage |
: |
Less than AC/DC 500V |
| Operating temperature |
: |
0 ~ 40 ℃ , < 85%RH (without condensation) |
| Storage temperature |
: |
-10 ~ 60 ℃ < 70%RH (without condensation) |
| Withstanding voltage |
: |
AC 2000V/1 minute between CT and outer case |
| Auto power off |
: |
Approx. 10 minutes after power on |
| Power supply |
: |
LR03,AM-4 or AAA size Alkaline battery×3 |
| Dimension |
: |
64(W)×195(H)×24(D)mm(Main CT) 25(W)×114(H)×19(D)mm(Auxiliary CT) |
| Weight |
: |
Approx.190g |
| Accessories |
: |
| Carrying case |
: |
1 |
| Instruction manual |
: |
1 |
| Batteries |
: |
3 |
| Auxiliary CT (CTP-05-2) with 1.5m lead cable |
: |
1 |
|
Accuracy (23 ℃ ±5 ℃ , less than 85%RH)
| Function |
Range |
Resolution |
Accuracy(50/60Hz) |
| 2CT |
AC1000mA |
0.1mA |
±1% rdg ± 10dgt |
| AC10A |
0.001A |
±1% rdg ± 10dgt |
| Main CT |
AC20A |
0.01A |
±1% rdg ± 10dgt |
| AC200A |
0.1A |
0 ~ 100A : ± 1% rdg ± 10dgt 101 ~ 150A : ± 3% rdg ± 10dgt 151 ~ 200A : ± 6% rdg ± 10dgt |
|
|
PRODUCTS
|
Optional auxiliary CT
Model ZCT-18-2
|
SPEC
|
|
| CT inside size |
: |
φ18mm |
| Limitation of circuit voltage |
: |
Less than AC 600V |
| Dimension |
: |
45(W)×140(H)×21(D)mm |
|