High Frequency AC/DC clamp adaptor
Model LAD-20(CE)
AC 0~20Arms, DC 0~±30A, 17mmφCT
PRODUCTS
|
FEATURES
- High frequency response DC to 100kHz.
- Data output function.
- Design to use with oscilloscope.
- AC adaptor is optionally available.
- Compliant with RoHS directive.
|
SPEC
| SPECIFICATIONS |
| CT type |
: |
Clamp method |
| Safety standard |
: |
IEC 61010-1,IEC61010-2-032,Installation CategoryⅡ 600V or Category Ⅲ 300V |
| Current detecting method |
: |
Magnetic balance method |
| Measuring range |
: |
AC 0~20Arms
DC 0~±30A
|
| Output voltage |
: |
100mV/A |
| Accuracy |
: |
±1%rdg ± 5mA (DC~100kHz) (23℃±5℃, 80%RH or less) |
| Frequency characteristic |
: |
-1.5dB(DC ~100kHz) |
| Output impedance |
: |
>10kΩ//<100pF |
| Temperature coefficient |
: |
0.013%/℃ |
| Positioning error of conductor |
: |
<1% |
| Jaw opening capability |
: |
φ17mm |
| Output cable and connector |
: |
2m length, BNC connector |
| Limitation of circuit voltage |
: |
Less than AC/DC 300V |
| Withstanding voltage |
: |
AC 3700V 1 minute max. (Without AC adaptor) |
| Operating temperature |
: |
-10℃ ~ 60℃, 15%~85%RH( without condensation ) |
| Storage temperature |
: |
-20℃ ~ 85℃, <80%RH( without condensation ) |
| Power supply |
: |
9V Alkaline battery (6LR61)×1 |
| Power consumption |
: |
Approx. 20mA (at 0A input) |
| Size |
: |
70(W)×192(H)×25(D)mm |
| Weight |
: |
Approx. 280g |
|
| Accessories |
: |
| Carrying case |
: |
1 |
| Batteries |
: |
1 |
| Instruction manual |
: |
1 |
|
|