Big CT(φ80mm) I0/I0r Clamp Leaker
Model MCL-800IR

The high accurate live line clamp insulation resistance(MΩ) tester
PRODUCTS
MCL-800IR FEATURES
  • Easy and convenient live line insulation measurements with φ80mm CT window
  • The least influence from external magnetic field and noise
  • 0.001~9.999MΩ wide range indication
  • Super accurate ZCT enabled 0.001mA resolution
SPEC
SPECIFICATIONS
Current detection section
Detection method : Split core type ZCT
CT Inside Size : φ80mm
Withstanding voltage : AC 2000V,1 minute
Measurements section
Measuring function : AC Leakage current(Io),line current(I),Resistive leakage current(Ior),AC voltage(V)
Insulation resistance(MΩ)[Calculation value]
(Measuring range) :
AC Leakage current (Io)
line current(I)
: 0~10A (Auto-ranging)
Resolution:0.001mA
Resistive leakage current(Ior) : 0~10A (Auto-ranging)
Resolution:0.001mA
AC voltage (V) : 10~500V (1 range)
Resolution:0.1V
Insulation resistance(MΩ) : 0.001~9.999MΩ
Computation by current and voltage
input frequency : 50/60Hz(manual switching)
A/D conversion : Sequential comparison method
AC Coversion : Average sensing, true rms responding method
Display : LCD , Max. 9999 count with annunciators
Over range indication : "OL" mark on LCD
Data hold indication : "DH" mark on LCD
Low battery indication : "Battery" mark on LCD
Sampling rate : 2 times/sec.
Operating temperature : 0 ~ 40 ℃ , < 80%RH (without condensation)
Storage temperature : -10 ~ 60 ℃ < 80%RH (without condensation)
Withstanding voltage : AC 2000V/1 minute (between CT and handle)
Limitation of circuit voltage : Less than AC 500V for insulated cable
Auto power off : Approx. 10 minutes after last key operation
Power supply : LR03,AM-3 or AAA size Alkaline battery x 3
Power consumption : Approx.14mA
Battery life : Approx.48 hours continuous
Dimension/Weight : 71(W)x315(H)x37(D)mm/Approx.750g
Accessories : Batteries(LR03) x 3
Voltage input lead x 1set
Carrying case x 1
Instruction manual x 1
SPEC
Accuracy (23℃±5℃ , Less than 80%RH)
Function Range Resolution Accuracy (50/60Hz)
Voltage(V) 500V 0.1V ±1.0%rdg±10dgt (10.0 ~ 499.9V)
Line current
(I)
Leakage current
(I0)
10mA 0.001mA ±1.0%rdg±10dgt ( 0 ~ 9.999mA )
100mA 0.01mA ±1.0%rdg±10dgt(10.00~99.99mA)
1000mA 0.1mA ±1.0%rdg±10dgt(100.0~999.9mA)
10A 0.001A ±1.0%rdg±10dgt ( 1.00 ~ 9.999A)
Resistive
leakage current
(I0r)
10mA 0.001mA ±1.5%rdg±20dgt ( 0 ~ 9.999mA )
100mA 0.01mA ±1.5%rdg±15dgt(10.00~99.99mA)
1000mA 0.1mA ±1.5%rdg±15dgt(100.0~999.9mA)
10A 0.001A ±1.5%rdg±15dgt ( 1.00 ~ 9.999A)