Multi Measuring Instruments Co.,Ltd. Japanese Chinese
Google
 

Digital harmonics tester

Digital Harmonics Clamp Tester

PRODUCTS
AC Leakage Current, 400mA/4A/40A/300A
Harmonics current, 40mmφCT
Model HWT-300
Digital Harmonics Clamp Tester. Model HWT-300
FEATURES
  • Harmonics and leakage current measurements.
  • Data-hold and Auto power off function.
  • The best tool to measure up to 25th harmonics current in the field.
  • Analog data output function.
Show detail Catalog PDF
DETAIL
SPEC
SPECIFICATIONS
Measuring method : Dual slope integration mode
Input frequency : 45Hz~65Hz
Display : 3.5 digit LCD, max. reading of 3999
Jaw opening capability : 40mmφ
Data output : DC 100mV for full scale(400mA/4A/40A ranges)
DC75mV for full scale(300A range)
Accuracy ±1% of full scale
Output impedance 10kΩ or less
Over range indication : "OL" mark on LCD
Low battery indication : "Battery" mark on LCD
Data hold indication : "DH" mark on LCD
Sampling : 2 times/sec
Withstanding voltage : AC 2200V 1 minute max. (Between the core of CT and outer case)
Affection of magnetic field : 3mA or less (at 100A nearby conductor)
Limitation of circuit voltage : Less than AC 600V
Operating temperature : 0℃ to 40℃, 80%RH max. ( Without condensation )
Storage temperature : -10℃ to 60℃, 70%RH max. ( Without condensation )
Power supply : 1.5V (AM-4, LR03 or AAA)×3 or AC adaptor(Option)
Power consumption : 13mA
Auto power off : Approx.10 minutes later after power on
Battery life : Approx.50 hours continuous
Size : 68(W)×207(H)×33(D)mm
Weight : Approx. 430g
Accessories :
Hard carrying case : 1
Instruction manual : 1
Batteries : 3
Option : AC adaptor
Accuracy : (23℃±5℃, 80%RH or less)
Range Resolution Accuracy Max.input
AC 400mA 0.1mA ±1.0% rdg ± 8 dgt AC 300Arms
AC 4A 1mA
AC 40A 10mA
AC 300A 100mA ±1% of full scale
Harmonics mode
Measuring method : Synchronous filter
Measurable harmonics : Fundamental to 25th harmonics
Minimum input : More than 5% of full scale in each range
Accuracy : ±1%rdg±5 dgt (23℃±5℃)
Error by neighboring harmonics
Harmonics Neighboring harmonics component
ratio against current or voltage
Typical accuracy
5th 65% ±3%rdg ± 5dgt
7th 41% ±3.5%rdg ± 5dgt
11th, 13th 20% ±4%rdg ± 5dgt
15th~25th 10% ±5%rdg ± 5dgt