search WWW
search Multi Site
AC/DC Clamp tester/leaker
AC/DC Clamp tester/leaker
(for AC/DC current and leakage current)
Model 230 AC/DC Mini clamp tester
(23mmφCT, ACA, DCA)
Model 240 AC/DC Mini clamp tester
(30mmφCT, ACA, DCA)
Model 250 AC/DC Mini clamp tester
(40mmφCT, ACA, DCA)
Model 260 AC/DC Digital clamp tester
(55mmφCT, ACA, DCA, ACV, DCV, Hz, Ω)
Model 270 AC/DC Digital clamp tester
(55mmφCT, ACA, ACV/True rms, DCA, DCV, Hz, Ω)
Model 280 AC/DC Mini clamp tester
(30mmφCT, ACA, DCA ACV, DCV, Ω)
Model 290RMS AC/DC Digital clamp tester
(30mmφCT, ACA, ACV/True rms, DCA, DCV, , Ω)
Model 600 AC/DC Digital clamp leaker
(30mmφCT, AC/DC leakage current)
Model 700 AC/DC Digital clamp milliammeter
(5mmφCT, AC/DC leakage current)
Model 730 AC/DC Digital clamp milliammeter
(30mmφCT, AC/DC leakage current)
List of MEASURING INSTRUMENTS
HOME
Page toTOP
AC/DC Digital Clamp Tester
PRODUCTS
AC/DC Current, 40A/400A/2000A, 55mmφ CT
Model 260
(CE)
FEATURES
Wide current measurements with tear drop type 55mmφCT up to 2000A.
Data-hold and Auto power off function.
Additional AC/DC voltage, resistance, diode test, continuity check.
Auto zero adjustment for DC current offset.
Conform to IEC safety requirements.
≫
Show detail
≫
Catalog PDF
DETAIL
SPEC
SPECIFICATIONS
Safety standard
:
IEC 61010-1, IEC 61010-2-032
Installation CategoryⅢ600V phase to earth.
E.M.C. standard
:
EN 61326
Measuring method
:
Dual slope integration mode
AC conversion
:
Average sensing rms reading
Display
:
3.5 digit LCD, max. reading of 3999
Jaw opening capability
:
55mmφ
Over range indication
:
Blanking of all digits except MSD 1
Low battery indication
:
"Battery" mark on LCD
Data hold indication
:
"DH" mark on LCD
Sampling
:
2 times/sec
Withstanding voltage
:
AC 5500V 1 minute max. (Between the core of CT and outer case)
Operating temperature
:
0℃ to 40℃, 80%RH max. ( Without condensation )
Storage temperature
:
-10℃ to 60℃, 70%RH max. ( Without condensation )
Power supply
:
1.5V (AM-4, LR03 or AAA)×2
Power consumption
:
14mW
Auto power off
:
Approx. 10 minutes later after power on
Battery life
:
85(W)×240(H)×34(D)mm
Weight
:
Approx. 350g
Accessories
:
Hard carrying case
:
1
Instruction manual
:
1
Test lead
:
1set
Batteries
:
2
Accuracy
(23℃±5℃, 80%RH or less)
Function
Range
Resolution
Accuracy
Max. input
ACA(50/60Hz)
DCA
Manual range
40A
0.01A
±2%rdg±8 dgt
AC/DC2000A
400A
0.1A
±1.5%rdg±8 dgt
2000A
1A
ACV(50/60Hz)
DC V
Auto/Manual
range
400mV
0.1mV
±1.2%rdg±8 dgt
AC/DC 600Vrms
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Frequency(Hz)
Auto range
100Hz
0.01Hz
±0.5%rdg±3 dgt
AC/DC 600Vrms
1000Hz
0.1Hz
10kHz
0.001kHz
100kHz
0.01kHz
1000kHz
0.1kHz
Resistance(Ω)
Auto/Manual
range
400Ω
0.1Ω
±1.5%rdg±8 dgt
Input protection
4kΩ
0.001kΩ
250 Vrms
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4000kΩ
1kΩ
Continuity check
400Ω
0.01Ω
Continuity beeper
250Vrms
Approx. < 40Ω
Diode test
3V
0.001V
±10%rdg±3 dgt
250Vrms