AC clamp leaker

Mini AC Leakage Current Clamp Tester

PRODUCTS
AC Leakage Current, 2mA /20mA /60A, 40mmφ CT
Model 340
Mini Digital Clamp Leaker. Model 340
FEATURES
  • 40mmφCT window and ultra compact size.
  • Least affection from the external magnetic field.
  • Accurate current measurements.(AC1μA-60A)
Show detail Catalog PDF
DETAIL
SPEC
SPECIFICATIONS
Safety standard : IEC 61010-1, IEC 61010-2-032, Installation
CategoryⅡ600V or CategoryⅢ300V.
Measuring method : Dual slope integration mode
Display : 3.5 digit LCD, max. reading of 1999
Range : AC 0~2mA/20mA/60A
Accuracy : 23℃±5℃ 80%RH or less (50/60Hz)
Range Resolution Accuracy
AC 2mA 1μA ±1.0% rdg ± 5dgt
AC 20mA 10μA
AC 60A 100mA ±1.0% rdg ± 5dgt(0~50A)
±5.0% rdg ± 5dgt(50A~60A)
Jaw opening capability : 40mmφ
Over range indication : Blanking of all digits except MSD 1
Low battery indication : "B" mark on LCD
Data hold indication : "DH" mark on LCD
Sampling : 2 times/sec
Withstanding voltage : AC 3700V 1 minute max. (Between the core of CT and outer case)
Operating temperature : 0℃ to 40℃, 80%RH max. ( Without condensation )
Storage temperature : -10℃ to 60℃, 70%RH max. ( Without condensation )
Power supply : 1.55V (SR-44, LR-44)×2
Power Consumption : 3.5mW
Battery life : Approx. 80 hours(LR-44)
Size : 68.5(W)×175(H)×23(D)mm
Weight : Approx. 145g
Accessories :
Soft case : 1
Instruction manual : 1
Batteries LR-44(1.55V) : 2