Multi Measuring Instruments Co.,Ltd. Japanese Chinese
Google
 

AC clamp leaker

Mini AC Leakage Current Clamp Tester

PRODUCTS
AC Leakage Current, 30mA /300mA, 30/300A, 40mmφ CT
Model 140 (CE)
Mini Digital Clamp Leaker. Model 140 (CE)
FEATURES
  • 40mmφCT window and ultra compact size.
  • Least affection from the external magnetic field.
  • Wide current measurements.(AC0.01mA-300A)
Show detail Catalog PDF
DETAIL
SPEC
SPECIFICATIONS
Safety standard : IEC 61010-1, IEC 61010-2-032
Installation CategoryⅡ600V or CategoryⅢ300V.
E.M.C. standard : EN 61326
Measuring method : Dual slope integration mode
Display : 3.5 digit LCD, max. reading of 3200
Range : AC 0~30mA/300mA, 30A/300A, 2 range manual
Accuracy : 23℃±5℃ 80%RH or less (50/60Hz)
Range Resolution Accuracy
AC 30/300mA 0.01mA ±1.2% rdg ± 5dgt
AC 30/300A 0.01A 0~200A : ±1.2% rdg ± 5dgt
200~250A : ±3.0% rdg ± 5dgt
250~300A : ±5.0% rdg ± 5dgt
Jaw opening capability : 40mmφ
Over range indication : "OL" mark on LCD
Low battery indication : "Battery" mark on LCD
Data hold indication : "DH" mark on LCD
Sampling : 2 times/sec (Digital display)
12 times/sec (Bar graph display)
Withstanding voltage : AC 3700V 1 minute max. (Between the core of CT and outer case)
Operating temperature : 0℃ to 40℃, 80%RH max. ( Without condensation )
Storage temperature : -10℃ to 60℃, 70%RH max. ( Without condensation )
Power supply : 1.55V (SR-44, LR-44)×2
Power Consumption : 5mW
Auto power off : Approx. 10 minutes later after power on
Battery life : Approx. 50 hours(LR-44)
Size : 64(W)×162(H)×23(D)mm
Weight : Approx. 125g
Accessories :
Soft case : 1
Instruction manual : 1
Batteries LR-44(1.55V) : 2