Digital Clamp Tester with 80mmφ CT
PRODUCTS
|
AC Leakage Current, 200mA/2A/20A /200A/1000A, 80mmφ CT
Model MCL-800D
|
FEATURES
- 80mmφCT window and wide current measurements from 0.1mA to 1000A.
- DCmV analog data output for recorder.
- Least affection from the external magnetic field.
|
|
≫ Show detail
≫ Catalog PDF
|
DETAIL
SPEC
| SPECIFICATIONS |
| Measuring method |
: |
Dual slope integration mode |
| Display |
: |
3.5 digit LCD, max. reading of 1999 |
| Accuracy |
: |
23℃±5℃ 80%RH or less (50/60Hz)
| Range |
Resolution |
Accuracy |
| AC 200mA |
0.1mA |
±2.0% rdg ± 5 dgt |
| AC 2A |
1mA |
| AC 20A |
10mA |
| AC 200A |
0.1A |
| AC 1000A |
1A |
|
| Jaw opening capability |
: |
80mmφ |
| Over range indication |
: |
Blanking of all digits except MSD 1 |
| Low battery indication |
: |
"B" mark on LCD |
| Data hold indication |
: |
"H・D" mark on LCD |
| Sampling |
: |
2 times/sec |
| Sampling |
: |
2 times/sec |
| Data output |
: |
DC100mV (for full scale) |
| Limitation of circuit voltage |
: |
Less than AC 600V |
| Withstanding voltage |
: |
AC 2000V 1 minute max. (Between the core of CT and outer case) |
| Operating temperature |
: |
0℃ to 40℃, 80%RH max. ( Without condensation ) |
| Storage temperature |
: |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
| Power supply |
: |
1.5V (AM-4, LR03 or AAA)×2 |
| Power consumption |
: |
3 mW |
| Battery life |
: |
Approx. 350 hours ( Alkaline batteries ) |
| Size |
: |
138(W)×225(H)×37(D)mm |
| Weight |
: |
Approx. 500g |
| Accessories |
: |
| Hard carrying case |
: |
1 |
| Instruction manual |
: |
1 |
| Batteries |
: |
2 |
|
|